Sample Rate Conversion Comparison
Adobe Audition   CS6        Quality 100%, Pre/Post Filter on
[Ideal Response]           

Sample Rate Conversion Results


  Adobe Audition   Digital audio workstation featuring both waveform editing and multi-track mixing

  Overall Balanced Quality 80.29 %  Overall Balanced Quality 100.00 %


Bit depth, whilst a SRC might accept 64 bit floating point, internally it might process at a much lower bit depth, this test checks different bit depths:

     16 bit      24 bit     32 bit float     32 bit     64 bit float     16 bit      24 bit     32 bit float     32 bit     64 bit float


SRC routines can introduce a delay at the start:

    Calculated delay 0 samples   Quality Score 100%    Calculated delay 0 samples   Quality Score 100%



Spectrogram of a sweep 1 to 22 kHz


A sine sweep from 1 to 22 kHz the ideal plot is a single strong red line. Issues with aliasing effects or filter cutoff would show as extra lines. Noise would appear as dots across the plot (instead of a black background). [96 kHz source resampled to 44 kHz]

   Quality Score 94.84%
(click image to view full size)
   Quality Score 100%
(click image to view full size)





Spectrogram of a sweep 1 to 22 kHz (extended)


The source signal included a sine sweep all the way up to 44 kHz, however when downsampled to 44 kHz the highest frequency which can be represented is 22 kHz. This plot would show if the sine above 22 kHz is filtering down into the plot, there should be nothing plotted after 10 seconds. [96 kHz source resampled to 44 kHz]

(click image to view full size)
(click image to view full size)





Aliasing


A 23 kHz sine at -4 dBFS over a low white noise floor (about -146 dBFS/Hz) for 10 seconds. The plot shows power spectral density in dBFS/Hz. The ideal plot is a continuous line on the test-noise line, with the 23 kHz sine removed completely; anything it leaves appears as its alias at 21.1 kHz. Many SRC routines engage a gradual filter at 20 kHz which would be visible on this plot. The grey lines show where the rounding noise of 16, 24 and 32 bit files lies on this scale. [96 kHz source resampled to 44 kHz]

   Quality Score 100%
(click image to view full size)
   Quality Score 100%
(click image to view full size)





Nyquist Filter


Zoomed on nyquist frequency (22.050 kHz), the bandwidth of the SRC is displayed. A SRC with 100% bandwidth, that is full freqency preservation would be a straight line of noise. [96 kHz source resampled to 44 kHz]

   Quality Score 99.12%
(click image to view full size)
   Quality Score 100%
(click image to view full size)





Intermodulation Harmonic Distortion


Two sine waves, one at 64.6 Hz, -6 dBFS and the second at 6998 Hz, -18.0412 dBFS, which equals quarter the amplitude of the first sine. This test will highlight aliasing and the dynamic range of processing. It will also show if dither has been applied, look for a raised noise floor on the plot. The plot is scaled so each tone reads its own peak level (-6 and -18 dBFS); noise is shown per analysis bin (about 22 Hz), and the grey lines show 16, 24 and 32 bit rounding noise on that same scale. [96 kHz source resampled to 44 kHz]

(click image to view full size)
(click image to view full size)





Intermodulation Harmonic Distortion (difference)


The difference between the ideal and measured signals from the Intermodulation Harmonic Distortion test. [96 kHz source resampled to 44 kHz]

   Quality Score 44.15%
(click image to view full size)
   Quality Score 100%
(click image to view full size)





Impulse Frequency


A frequency response displaying leakage beyond the ideal frequency response.
Impulses are at sample positions n so that {n mod 320} is a permutation of {0, 1, 2, . . . , 319}. All fractional differences in sample positions between input and output signal are addressed exactly once. The output signal is upsampled to 14.112 MHz and the impulse responses are added to obtain a high resolution impulse response. [96 kHz source resampled to 44 kHz]

   Quality Score 56.26%
(click image to view full size)
   Quality Score 100%
(click image to view full size)





Impulse Response


Displays the phase response, most SRC balance the response with pre and post ringing, personal preference might prefer a minimum phase response where there is no pre-ringing, the quality score is based mainly on reduction of pre-ringing. [96 kHz source resampled to 44 kHz]

   Quality Score 18.09%
(click image to view full size)





Impulse Phase


The actual phase across the frequency range. [96 kHz source resampled to 44 kHz]

(click image to view full size)
(click image to view full size)





Impulse Passband


Displays the SRC filter used close to the nyquist frequency. [96 kHz source resampled to 44 kHz]

(click image to view full size)
(click image to view full size)





Impulse Transition


A zoomed plot of the nyquist frequency showing the filter response. If 'Nyquist Foldback Detected (aliasing)' is shown, it means that frequencies higher than the Nyquist were detected on the impulse, a sign that Nyquist foldback is used which can artificially inflate the Nyquist Filter (bandwidth) score, if detected then a penalty of 0.5% is applied to the Nyquist filter score, effectively nulling the foldback advantage. [96 kHz source resampled to 44 kHz]

  Nyquist Foldback Detected (aliasing)
(click image to view full size)
(click image to view full size)





Gapless Sine


A sine wave is split into two, both are resampled independently. This plot is the two signals joined back together. The blue line shows the transition after resampling. Deviation from sine wave shape likely means an audible glitch. Any value over +1 would clip if later not corrected. [96 kHz source resampled to 44 kHz]

   Quality Score 0.29%
(click image to view full size)
   Quality Score 100%
(click image to view full size)





Gapless Sine (frequency plot)


A frequency plot of the gapless sine test. [96 kHz source resampled to 44 kHz]

(click image to view full size)
(click image to view full size)





Alias Rejection


How well the SRC removes the copies it makes of every input frequency, measured without noise. Inside a resampler each frequency is copied to multiples of 96 kHz plus and minus that frequency, and input above 22.05 kHz must not fold back; whatever the filter lets through lands at a known frequency in the output. Every one of those positions is measured as the sweep passes (continuously, down to about 190 dB) and for both tones of the two-tone test (down to about 225 dB). The plot shows each copy's level against the frequency it had inside the resampler, which traces the filter's stopband. The score is the worst rejection found: 180 dB or more scores 100%. [96 kHz source resampled to 44 kHz]

   Quality Score 100%
(click image to view full size)
   Quality Score 100%
(click image to view full size)
   
Uploaded by Case
   